Resumo do Conteúdo

Página 1 - System Manual

BreezeACCESS II System ManualSW Version 4.5June 2004P/N: 213801

Página 2

4BreezeACCESS 4.5 System ManualSystem Manual Book 3:CommissioningSetting Basic Parameters ... 1-1Accessing the Mon

Página 3 - Warranties; Disclaimers

1-6BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0Scrambling Mode Enhanced Applicable only if HDM Mode is enabledManual Sequence Definitio

Página 4 - FCC Radiation Hazard Warning

Setting Basic Parameters 1-7BreezeACCESS Version 4.5 System ManualOnce the basic parameters are configured, the unit must be reset in order to activa

Página 5 - Important Notice

1-8BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0Once the basic parameters are configured, the unit must be reset in order to activate the

Página 6

Chapter 2Optimizingthe Wireless LinkThis chapter explains how to optimize the performance of the wireless link of BreezeACCESS Subscriber Units and in

Página 7 - Table of Contents

2-2BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0 Configuring the Maximum Data Rate (Subscriber Units)The BreezeACCESS units transmit at

Página 8 - System Manual Book 2:

Optimizing the Wireless Link 2-3BreezeACCESS Version 4.5 System ManualAligning the Antenna of the SU-A/E Subscriber Unit1. Verify that the outdoor un

Página 9

2-4BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0Configuring the Transmit Power of the AU-REThe transmitted output power of the AU should

Página 10 - Commissioning

Optimizing the Wireless Link 2-5BreezeACCESS Version 4.5 System ManualTable 2-2: Transmit Power Control for FCC Certified AntennasTable 2-3: Transmit

Página 11 - Manual Revision 1.0

2-6BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0Positioning the SU-I or SU-R Subscriber Unit with Omni Antennas for Optimal OperationTo i

Página 12 - Operations and Administration

Optimizing the Wireless Link 2-7BreezeACCESS Version 4.5 System ManualAligning the External Antenna of SU-R and SU-I-D UnitsFor Subscriber Units with

Página 13 - System Manual: Appendices

Table of Contents 5Manual Revision 1.0BS-PS DC Power Supply Module LEDs ... 4-5BS-PS-AC AC Power Supply Module LEDs ...

Página 14

2-8BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0

Página 15

Chapter 3BS-GU ConnectorsThis chapter explains how to connect external devices to the AL IN and AL OUT connectors of the BS-GU module. It also include

Página 16

3-2BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0Connecting External Devices to the BS-GU AL IN and/or AL OUT Connectors Open-ended cables

Página 17 - Introduction

Connecting External Alarm Devices 3-3BreezeACCESS Version 4.5 System ManualAlarms Out CableTable 3-2: Alarms Out CableGPS CableCable Type: EIA RS-422

Página 18 - Introducing BreezeACCESS

3-4BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0Figure 3-1 shows a 9-pin Micro D-Type Connector (cable side), and Figure 3-2 shows a 12-p

Página 19 - Components

Connecting External Alarm Devices 3-5BreezeACCESS Version 4.5 System ManualSYNC CableCable Type: EIA RS-422 3X2X25AWG +1X2X24 AWG FTP Shielded cable.

Página 20 - Premises Equipment)

3-6BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0

Página 21 - System Components

Chapter 4VerifyingProper OperationThis chapter explains how to confirm that the BreezeACCESS system is functioning properly and includes the following

Página 22

4-2BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0Verifying ConnectivityVerifying the Ethernet ConnectionOnce you have connected the unit t

Página 23 - Data and Voice Units:

Verifying Proper Operation 4-3BreezeACCESS Version 4.5 System ManualVerifying Proper Operation of the GU-A-BS GPS UnitWhen the unit is operating prop

Página 24 - Base Station Equipment

6BreezeACCESS 4.5 System ManualSystem Manual Book 4:Operations and AdministrationAccessing the Monitor Program ... 1-1Acces

Página 25

4-4BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0LED IndicatorsTo verify correct operation of the units, view the status of the relevant L

Página 26 - GU-A-BS GPS and Alarms System

Verifying Proper Operation 4-5BreezeACCESS Version 4.5 System ManualSU-NI and AU-NI Indoor Units LEDsTable 4-3: SU-NI and AU-NI Indoor Units LEDsBS-P

Página 27

4-6BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0BS-AU LEDsTable 4-6: BS-AU LEDsBS-GU LEDsTable 4-7: BS-GU LEDsName Description Functional

Página 28 - Access Unit

Verifying Proper Operation 4-7BreezeACCESS Version 4.5 System ManualSU-R LEDsTable 4-8: SU-R LEDsSU-I/SU-I-D LEDs Table 4-9: SU-I/SU-I-D LEDsName Des

Página 29

4-8BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0AU-I/AU-I-D LEDsTable 4-10: AU-I/AU-I-D LEDsName Description FunctionalityPOWER Power sup

Página 30 - Management Systems

BreezeACCESS II SW Version 4.5Revision 1.0System Manual Book 4:Operations and Administration

Página 32

Chapter 1Accessing theMonitor ProgramThis chapter explains how to access the monitor program. It also describes how to use the monitor program to set

Página 33 - Specifications

1-2BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Accessing the Monitor Program using the RS 232 MON Connector1. Use the mo

Página 34 - System Specifications

Accessing the Monitor Program 1-3BreezeACCESS Version 4.5 System ManualAccessing the Monitor Program using Telnet1. Connect a PC to the Ethernet port

Página 35 - Data Communication

Table of Contents 7Manual Revision 1.0Hopping Parameters (GU) ...2-120Alarm Parameters (GU) ...

Página 36

1-4BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Screens option is displayed. Users with this access level cannot access t

Página 37 - GU-RA to BS-GU Communication

Chapter 2Menusand ParametersThis chapter describes the BreezeACCESS configuration menus and parameters. It includes the following sections:! Main Menu

Página 38 - Standards Compliance, General

2-2BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Main MenuFrom the Main Menu you can access the following menus, depending

Página 39 - Physical Specifications

Menus and Parameters 2-3BreezeACCESS Version 4.5 System ManualInfo Screens MenuFigure 2-1: Info Screens MenuThe Info Screens menu enables viewing of

Página 40 - Mechanical

2-4BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0" Version After Reset – Displays the software version that will be u

Página 41

Menus and Parameters 2-5BreezeACCESS Version 4.5 System ManualThe following parameters appear for GPS Modules only:! Unit Status – Indicates the stat

Página 42

2-6BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Unit Control MenuThe Unit Control menu includes the following options:! R

Página 43 - SU-I/I-D

Menus and Parameters 2-7BreezeACCESS Version 4.5 System ManualTable 2-1: Parameters not changed after Set Complete/Partial Factory DefaultsParameter

Página 44 - AU-I/I-D

2-8BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0VLAN Relaying Support÷÷Relaying VLAN IDs÷÷VLAN Priority – Data÷÷VLAN Prio

Página 45 - SU-R Subscriber Units

Menus and Parameters 2-9BreezeACCESS Version 4.5 System Manual# Set Complete Operator Defaults – Available only with Administrator access rights. Set

Página 46

8BreezeACCESS 4.5 System ManualAppendix F: Hopping Sequences ... F-1Hopping Standard: Australia ...

Página 47

2-10BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0! Change Password – Changes the password(s). A user with Installer acces

Página 48

Menus and Parameters 2-11BreezeACCESS Version 4.5 System Manualfor storing it. Events are classified according to their severity level: Trace (lowest

Página 49 - Equipment

2-12BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0c. The address of the TFTP server and the proper name of the configurati

Página 50 - Packing Lists

Menus and Parameters 2-13BreezeACCESS Version 4.5 System Manual! Remote Set IP (AU only) - A sub-menu that enables setting the IP parameters of an SU

Página 51 - Installation

2-14BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Basic Configuration MenuThe Basic Configuration menu includes all the pa

Página 52

Menus and Parameters 2-15BreezeACCESS Version 4.5 System ManualVLAN Parameters! VLAN ID – Management (AU and SU without voice support) (see page 2-73

Página 53 - Equipment Locations

2-16BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Site Survey MenuThe Site Survey menu provides various tests and counters

Página 54 - Indoor Equipment

Menus and Parameters 2-17BreezeACCESS Version 4.5 System ManualWireless Link CountersThe unit transmits data frames received from the Ethernet port,

Página 55 - Installing the Outdoor Unit

2-18BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0If the ACSE Option is enabled, then in addition to the total count, ther

Página 56 - Table 1-5: AU-RA/RE LEDs

Menus and Parameters 2-19BreezeACCESS Version 4.5 System Manual! Bad fragments received – Displays the number of frames received from the wireless me

Página 57 - IF Based Equipment

BreezeACCESS II SW Version 4.5Revision 1.0System Manual Book 1:System Description

Página 58

2-20BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0The Rx, Tx and RTx per hop counters accumulate the number of applicable

Página 59

Menus and Parameters 2-21BreezeACCESS Version 4.5 System Manual! Start Sending – Starts transmission of ping frames.! Stop Sending – Stops the transm

Página 60 - (SU-RE and AU-RE)

2-22BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0" Sp (Special): 5 Addresses that always exist:# The MAC address of

Página 61 - Indoor Unit

Menus and Parameters 2-23BreezeACCESS Version 4.5 System Manual" The SW version of the SU.Table 2-2: Association Process (Active Scanning)* When

Página 62

2-24BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Per-rate Counters (AU and SU)Resets or displays the per-rate counters. T

Página 63 - Station Equipment

Menus and Parameters 2-25BreezeACCESS Version 4.5 System ManualAU Alarms (IF-based AU Only)The AU Alarms feature enables to identify and alert upon t

Página 64 - The BS-PS

2-26BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0In addition, the Average Rate is also calculated for each of the above t

Página 65 - The BS-PS-AC

Menus and Parameters 2-27BreezeACCESS Version 4.5 System ManualBased on the RSSI information responses from the SUs, the AU performs a calculation of

Página 66 - The BS-AU

2-28BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Association TestsIf the AU was reset 3 times because no SU became associ

Página 67 - Installation Procedure

Menus and Parameters 2-29BreezeACCESS Version 4.5 System ManualAll Associations Lost Alarm Severity: MajorOn Conditions: No response from any SU to t

Página 69 - Installing the GU-A-BS GPS

2-30BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0High Retransmissions Rate Alarm Severity: Minor, MajorOn Conditions: Min

Página 70 - Table 1-10: BS-GU Connectors

Menus and Parameters 2-31BreezeACCESS Version 4.5 System ManualHigh Dropped Frames Rate Alarm Severity:Minor, MajorOn Conditions: Minor Severity Alar

Página 71 - Figure 1-14: GPS Installation

2-32BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0High CRC Error Rate Alarm Severity: Minor, MajorOn Conditions: Minor Sev

Página 72 - Installing the BS-GU module

Menus and Parameters 2-33BreezeACCESS Version 4.5 System ManualHigh Duplicate Frames Rate Alarm Severity: Minor, MajorOn Conditions: Minor Severity A

Página 73 - SU-R Units

2-34BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0The AU Alarms MenuThe AU Alarms menu enables to configure relevant param

Página 74

Menus and Parameters 2-35BreezeACCESS Version 4.5 System ManualThe default parameters for these alarms is as follows:"Show Traffic Statistics Pa

Página 75 - Installation Guidelines

2-36BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Default value: 15 (dB)." Show AU Rx Power Test Parameters and Data

Página 76 - Lightning Protection

Menus and Parameters 2-37BreezeACCESS Version 4.5 System ManualAdvanced Configuration MenuThe Advanced Configuration menu provides access to all the

Página 77 - Installing SU-R Indoor Units

2-38BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0! DHCP Client " DHCP Options – Displays the current status of the D

Página 78 - Supply and to the CPE

Menus and Parameters 2-39BreezeACCESS Version 4.5 System ManualModulation (HDM) mode. The HDM mode enables flexible selection of the frequencies and

Página 79 - Indoor SU-R Units

Chapter 1IntroductionThis chapter introduces the BreezeACCESS system, its components and its functions.About This Chapter

Página 80

2-40BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Table 2-3: Country Standards Supported by BreezeACCESS IIRefer to Append

Página 81 - SU-I and AU-I Units

Menus and Parameters 2-41BreezeACCESS Version 4.5 System Manualthe basic sequence and the number of hopping frequencies also define the hopping shift

Página 82

2-42BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0! Scrambling Definitions - The Scrambling Definitions menu enables defin

Página 83 - Indoor SU-I and AU-I Units

Menus and Parameters 2-43BreezeACCESS Version 4.5 System Manual1. The first channel in the basic scrambled sequence is frequency 1. Frequency 1 (i

Página 84

2-44BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Valid values: 1 to Number of Hopping Frequencies minus 1, provided it me

Página 85

Menus and Parameters 2-45BreezeACCESS Version 4.5 System ManualChannels Spanning FactorHopping Sequences71234561, 2, 3, 4, 5, 6, 7 1, 3, 5, 7, 2

Página 86

2-46BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.014 135911131, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 141, 4, 7, 10, 13,

Página 87 - Connectors and LEDs

Menus and Parameters 2-47BreezeACCESS Version 4.5 System Manual19 1 234567891011121314151617181, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16,

Página 88 - Table 3-2: SU-I LEDs

2-48BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.023 123456789101112131415161718192021221, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,

Página 89 - Table 3-3: AU-I LEDs

Menus and Parameters 2-49BreezeACCESS Version 4.5 System ManualOperational Hopping Sequence Definition Using the Hopping Sequence (Shift) ParameterTh

Página 90 - Wall Mounting the Unit

1-2BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0Introducing BreezeACCESSBreezeACCESS IP Broadband Wireless Access system is an IP ba

Página 91

2-50BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Max. Hopping Sequence (Shift) (channels) = Number of hopping frequencies

Página 92

Menus and Parameters 2-51BreezeACCESS Version 4.5 System ManualThe following formula can be used for calculating the actual hopping sequence: PS(j)={

Página 93

2-52BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Table 2-7: Hopping Sequence (Shift) Implementation, Standard Scrambling

Página 94

Menus and Parameters 2-53BreezeACCESS Version 4.5 System ManualP0(i) is element number in the basic hopping sequence (s=0).For example, in the basic

Página 95 - Basic Parameters

2-54BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Hopping Sequence (Shift) Range and Default ValueThe permitted range for

Página 96

Menus and Parameters 2-55BreezeACCESS Version 4.5 System ManualThe default value is ESSID1. ! Operator ESSID Parameters (AU only) – The Operator ESSI

Página 97 - Configuration option

2-56BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0AUs it can communicate with. At the end of the scanning period, the SU r

Página 98 - Operating the Monitor Program

Menus and Parameters 2-57BreezeACCESS Version 4.5 System Manual" Preferred AU MAC Address – Defines a specific AU with which the SU should assoc

Página 99 - Configuring Basic Parameters

2-58BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Power Control ParametersThe power control parameters enable to optimize

Página 100 - Manual Revision: 1.0

Menus and Parameters 2-59BreezeACCESS Version 4.5 System Manual! Transmit Power Control (IF-based units only – SU-A/E, AU-BS and AU-NI) – Controls th

Página 101 - GU-A-BS Units

Chapter 2SystemComponentsThis chapter describes BreezeACCESS system components. It includes the following sections:! Subscriber Units (Customer Premi

Página 102

2-60BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Table 2-9 -.: Transmit Power OutputNew BreezeACCESS II AU-RA/RE-HP outdo

Página 103 - Optimizing

Menus and Parameters 2-61BreezeACCESS Version 4.5 System ManualTable 2-10: Transmit Power Output in New AU Outdoor Units! Power Level - Applicable to

Página 104 - Data Rate (Subscriber Units)

2-62BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0! Transmit Level - Applicable to SU-I/AU-I units with HW version D or h

Página 105 - SU-A/E Subscriber Unit

Menus and Parameters 2-63BreezeACCESS Version 4.5 System ManualDefault value: 120 seconds." ATPC Power Level Step - The step size in percentages

Página 106 - Power of the AU-RE

2-64BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0range/speed trade-off), you may decide to limit the use of higher rates.

Página 107 - Optimizing the Wireless Link

Menus and Parameters 2-65BreezeACCESS Version 4.5 System Manualdecrease the overall performance and achievable network throughput. It should be incre

Página 108 - Operation

2-66BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0c. ACSE voice calls will be terminated (no slot will be allocated for th

Página 109

Menus and Parameters 2-67BreezeACCESS Version 4.5 System Manualreceive circuit is equivalent to reducing the level of the received signal (including

Página 110

2-68BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0including units that do not support voice, since they are also affected

Página 111 - BS-GU Connectors

Menus and Parameters 2-69BreezeACCESS Version 4.5 System Manual! Wireless Trap Threshold - Enables to define the threshold for the wireless quality t

Página 113 - GPS Cable

2-2BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0Subscriber Units (Customer Premises Equipment)The BreezeACCESS Subscriber Unit (SU)

Página 114

2-70BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0" Max Number of Association/Authentication Timeouts - A timer is st

Página 115 - SYNC Cable

Menus and Parameters 2-71BreezeACCESS Version 4.5 System Manual" Disable – No IP address based filtering" Activate Management IP Filter On

Página 116

2-72BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0! Enable Traps Sending - enables sending of SNMP Traps. The Traps that w

Página 117 - Proper Operation

Menus and Parameters 2-73BreezeACCESS Version 4.5 System Manual# The default of all three SNMP Traps IP Destinations is 0.0.0.0." SNMP Traps Com

Página 118 - Verifying Connectivity

2-74BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0# Frames received from the Wireless link port: ! Only tagged frames with

Página 119 - GU-A-BS GPS Unit

Menus and Parameters 2-75BreezeACCESS Version 4.5 System ManualTable 2-13: Management Port Functionality – AU, SU without Voice Support and GULegend:

Página 120 - LED Indicators

2-76BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0value of the VLAN ID – Voice & Management parameter. The table is va

Página 121 - BS-PS DC Power Supply Module

Menus and Parameters 2-77BreezeACCESS Version 4.5 System Manual# Trunk Link – Transfers only tagged frames, because all devices connected to it are V

Página 122 - BS-GU LEDs

2-78BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0or VLAN-unaware. This is equivalent to defining no VLAN support, as the

Página 123 - SU-I/SU-I-D LEDs

Menus and Parameters 2-79BreezeACCESS Version 4.5 System Manual# Show VLAN ID Forwarding List – Displays the values of the VLAN IDs that are included

Página 124 - AU-I/AU-I-D LEDs

System Components 2-3BreezeACCESS Version 4.5 System ManualFigure 2-1: BreezeACCESS SU-A/E Outdoor and Indoor UnitsBreezeACCESS II SU-A/E units are av

Página 125

2-80BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0BreezeACCESS Subscriber and Access Units support Layer 2 traffic priorit

Página 126

Menus and Parameters 2-81BreezeACCESS Version 4.5 System Manualparameter only impacts the way that other VLAN-aware devices will handle the packet. V

Página 127 - Monitor Program

2-82BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0supports quality of service based on IPv4 ToS, the value of this paramet

Página 128 - MON Connector

Menus and Parameters 2-83BreezeACCESS Version 4.5 System ManualThe Ethernet Broadcasting Filtering menu allows viewing and setting the following para

Página 129 - Program using Telnet

2-84BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Available selections are:" Disable– ARP Broadcast messages are filt

Página 130 - Operating the Monitor

Menus and Parameters 2-85BreezeACCESS Version 4.5 System Manualtransmitted by the AU back to the wireless link devices, as well as to the wired LAN.

Página 131

2-86BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Performance Parameters (AU and SU)The Performance Parameters menu includ

Página 132 - Main Menu

Menus and Parameters 2-87BreezeACCESS Version 4.5 System Manual! Minimum Contention Window – The BreezeACCESS system uses a special mechanism based o

Página 133 - Info Screens Menu

2-88BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0number of successful windows at a certain rate required to reach a decis

Página 134

Menus and Parameters 2-89BreezeACCESS Version 4.5 System Manual! Interference Avoidance Parameters: These parameters enable to define the interferenc

Página 135 - Show All Parameters

2-4BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0X=A: The outdoor radio unit includes an integral high gain flat antennaX=E: The outd

Página 136 - Unit Control Menu

2-90BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0" Noise Floor: Enables the user to set the equivalent noise level t

Página 137 - Menus and Parameters

Menus and Parameters 2-91BreezeACCESS Version 4.5 System Manualalgorithm is enabled, then the Runtime Noise Floor is the higher of the following two

Página 138

2-92BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0# Disable (No filtering).# IP Only (only IP Protocol packets pass).# Use

Página 139

Menus and Parameters 2-93BreezeACCESS Version 4.5 System ManualUnder normal conditions, the actual Information Rate (IR) will be between the applicab

Página 140

2-94BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Valid values are from 32 to 2200Kbps. The default value is 128Kbps."

Página 141

Menus and Parameters 2-95BreezeACCESS Version 4.5 System ManualDegradation Limit. Higher demand can be expected in cases of significant over subscrip

Página 142

2-96BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Transactions between the client and RADIUS server are authenticated thro

Página 143

Menus and Parameters 2-97BreezeACCESS Version 4.5 System Manual! Shared Secret – To define the key that will be used for encrypting the User Password

Página 144 - Basic Configuration Menu

2-98BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0server. The Accounting Parameters menu includes the following parameters

Página 145 - Security Parameters

Menus and Parameters 2-99BreezeACCESS Version 4.5 System ManualTable 2-19: Ethernet Vendor Specific Record Structure (Vendor Specific ID is 710)Secur

Página 146 - Site Survey Menu

System Components 2-5BreezeACCESS Version 4.5 System ManualThe following types of units are available:Data-only Units: Data and Voice Units: X=I: The

Página 147 - Wireless Link Counters

2-100BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0" Open System: An SU configured to Open System can be authenticate

Página 148

Menus and Parameters 2-101BreezeACCESS Version 4.5 System ManualThe default for all 4 keys is a string of 10 zeros (no key).Wireless Media SecurityWi

Página 149 - Support Only)

2-102BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Voice ParametersThe parameters in the Voice Parameters menu include the

Página 150 - Ping Test (AU, SU and GU)

Menus and Parameters 2-103BreezeACCESS Version 4.5 System Manual6 if ACSE Option is enabled. (covers all G729 codecs, including G729Annex A, G729wAnn

Página 151 - (Available in SU Only)

2-104BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0Protocol ParametersThe parameters in the Protocol Parameters menu inclu

Página 152

Menus and Parameters 2-105BreezeACCESS Version 4.5 System Manualan RCF containing the same timeToLive or a shorter timeToLive. After this time, the r

Página 153

2-106BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0" Stop Dialing Indicator: - contols the use of the # sign to indic

Página 154 - ATPC Counter (AU and SU)

Menus and Parameters 2-107BreezeACCESS Version 4.5 System ManualAvailable selections: " Speech (used by H.323 speech terminals)" Unrestrict

Página 155 - AU Alarms (IF-based AU Only)

2-108BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0gateway and sent over the IP network as IP fax packets (IFP) using UDP.

Página 156 - Power Tests

Menus and Parameters 2-109BreezeACCESS Version 4.5 System ManualDefault selection is Disable." Inter-Regional Prefix – Defines the prefix indica

Página 157

2-6BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0SU-R High-Power Indoor UnitsThe SU-R line includes small-footprint, high-power units

Página 158 - AU Alarms Summary

2-110BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0The default is EnableNational Telephony Parameters! Telephony Country S

Página 159 - All Associations Lost Alarm

Menus and Parameters 2-111BreezeACCESS Version 4.5 System Manual# Frequency 2 – The second of the two frequencies to be used for generating the appli

Página 160

2-112BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0" Min On-Hook Detect Time – The minimum time for decision on an on

Página 161

Menus and Parameters 2-113BreezeACCESS Version 4.5 System ManualRange: 30 to 330 (%).Default: country specific.# Min Inter-Digit Time – The minimum t

Página 162 - High CRC Error Rate Alarm

2-114BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0the Minimum Off-Hook Detection Current.Default: country specific."

Página 163

Menus and Parameters 2-115BreezeACCESS Version 4.5 System Manual" Ring DC Component - The DC component of the ring signal. The available options

Página 164 - The AU Alarms Menu

2-116BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0The following options are available:" Disable" ETSI 300 659 1

Página 165

Menus and Parameters 2-117BreezeACCESS Version 4.5 System Manual! V5 Pulse Parameters – These are the cadences used by the V5 features. Every cadence

Página 166

2-118BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0# Polarity in Talking State# Polarity when Called Party Hangs-up FirstT

Página 167 - Advanced Configuration Menu

Menus and Parameters 2-119BreezeACCESS Version 4.5 System Manualthe digital signal.Payload loopback occurs when voice coming from network is fed back

Página 168

System Components 2-7BreezeACCESS Version 4.5 System Manual! Standalone “Micro-Cell” Access Unit! AU-I/I-D miniature indoor units Modular Base Station

Página 169

2-120BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0" Foreign AC Ring voltage (mV)" Line State Test Result: Resul

Página 170

Menus and Parameters 2-121BreezeACCESS Version 4.5 System ManualHopping Parameters (GU)The Hopping Parameters Menu allows configuration of the hoppin

Página 171

2-122BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0antenna to generate the synchronization signals for the AUs. When two o

Página 172

Menus and Parameters 2-123BreezeACCESS Version 4.5 System Manual" Automatic Recovery Mode - Enables to control an automatic recovery process:# A

Página 173

2-124BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0! Show Alarm Parameters.Alarms In NamesThe Alarms In Names menu allows

Página 174

Menus and Parameters 2-125BreezeACCESS Version 4.5 System ManualAlarms Out ControlThe Alarms Out Control menu allows the functionality of the Alarms

Página 175

2-126BreezeACCESS Version 4.5 Operations and AdministrationManual Revision: 1.0" Name: Name according to the name defined in the Alarms In Names

Página 176

BreezeACCESS IISW Version 4.5Revision 1.0System Manual:Appendices

Página 178

Appendix A:ConfigurationDownload/UploadThis appendix describes the method of configuring a large number of BreezeACCESS units at once.

Página 179

2-8BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0Figure 2-4: BreezeACCESS Base Station Module and Outdoor UnitsBreezeACCESS II AU-A/E

Página 180

A-2BreezeACCESS Version 4.5 System ManualManual Revision: 1.0The Configuration Download/Upload feature in BreezeACCESS units simplifies the task of re

Página 181

Appendix B:Software VersionLoading ProcedureGeneralFirmware upgrades to the unit's FLASH memory are performed by a simple loading procedure using

Página 182

B-2BreezeACCESS Version 4.5 System ManualManual Revision: 1.06. To verify the connection, ping the unit’s IP address. Verify that ping replies are bei

Página 183

Appendix B B-3BreezeACCESS Version 4.5 System ManualWhen version loading is completed the following message is displayed:Loading operation has been co

Página 184 - ESSID Parameters

B-4BreezeACCESS Version 4.5 System ManualManual Revision: 1.01. From the Flash Memory Control menu select 2 - Use Current Version After Reset. The Use

Página 185 - Best AU Selection Parameters

Appendix B B-5BreezeACCESS Version 4.5 System ManualWhen loading is completed the following message is displayed: Loading operation has been completed

Página 186

B-6BreezeACCESS Version 4.5 System ManualManual Revision: 1.01. From the Flash Memory Control menu select 2 - Use Current Version After Reset. The Use

Página 187

Appendix D:RSSI to dBmConversion TableSU-A/E, AU-A/E RSSI dBM RSSI dBM71 -100 114 -6472 -99 115 -6374 -98 116 -6275 -97 118 -6177 -96 119 -6078 -95 1

Página 188 - Power Control Parameters

D-2BreezeACCESS Version 4.5 System ManualManual Revision: 1.0110 -68 151 -32111 -67 152 -31112 -66 153 -30113 -65

Página 189

Appendix D D-3BreezeACCESS Version 4.5 System ManualSU-R and SU-IRSSI dBM RSSI dBM 26 -100 81 -6427 -99 82 -6329 -98 83 -6230 -97 84 -6132 -96 85 -60

Página 190 - -.: Transmit Power Output

System Components 2-9BreezeACCESS Version 4.5 System ManualFigure 2-5: BreezeACCESS GU-A-BS System ComponentsThe BreezeACCESS BS-GU module is designed

Página 191

D-4BreezeACCESS Version 4.5 System ManualManual Revision: 1.0

Página 192

Appendix E:Parameters ListUnit Control ParametersParameter Unit Range DefaultRun-Time UpdatedChange Unit NameAll Up to 32 printable ASCII charactersE

Página 193

E-2BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Site Survey ParametersParameter Unit Range DefaultRun-Time UpdatedRSSI Display OptionAU,

Página 194

Appendix E E-3BreezeACCESS Version 4.5 System ManualIP ParametersDuplicate Frames Minor Alarm Minimum DeltaIF-based AU 0 – 100 (%) 5 (%) YesDuplicate

Página 195

E-4BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Air Interface ParametersParameter Unit Range DefaultRun-Time UpdatedESSID AU, SU Up to 3

Página 196

Appendix E E-5BreezeACCESS Version 4.5 System ManualPower Level SU-R, SU-I/AU-I units with HW version C or lower Low, High High NoTransmit Antenna SU-

Página 197

E-6BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Minimum Interval Between ATPC MessagesIF Based AU0-3600 (seconds)120 (seconds) YesRSSI Me

Página 198

Appendix E E-7BreezeACCESS Version 4.5 System ManualNetwork Management ParametersParameter Unit Range DefaultRun-Time UpdatedAccess To Network Manage

Página 199

E-8BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Send SU Wireless Quality TrapSU Disable Trap Sending,Enable Trap SendingEnable Trap Sendi

Página 200 - (AU, SU and GU)

Appendix E E-9BreezeACCESS Version 4.5 System ManualBridge ParametersParameter Unit Range DefaultRun-Time UpdatedVLAN ID-Data SU 1 – 4094 1 NoVLAN ID

Página 201 - Port options are available

2-10BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0Daisy-chained BS-GU modules use the synchronization signals generated by the first

Página 202

E-10BreezeACCESS Version 4.5 System ManualManual Revision: 1.0PPPoE Broadcast Override FilterSU Disable, Enable Disable YesARP Broadcast Override Filt

Página 203

Appendix E E-11BreezeACCESS Version 4.5 System ManualPerformance ParametersParameter Unit Range DefaultRun-Time UpdatedRTS Threshold AU, SU 20 – 1600

Página 204

E-12BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Adaptive Thresholds PeriodSU 1 – 60 (seconds) 15 (seconds) NoAdaptive Thresholds Fading

Página 205

Appendix E E-13BreezeACCESS Version 4.5 System ManualService ParametersParameter Unit Range DefaultRun-Time UpdatedUser Filtering OptionSU Disable,IP

Página 206

E-14BreezeACCESS Version 4.5 System ManualManual Revision: 1.0RADIUS ParametersParameter Unit Range DefaultRun-Time UpdatedUser Name SU Up to 64 prin

Página 207 - WARNING:

Appendix E E-15BreezeACCESS Version 4.5 System ManualSecurity ParametersParameter Unit Range DefaultRun-Time UpdatedAuthentication AlgorithmAU, SU Op

Página 208

E-16BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Voice ParametersParameter Unit Range DefaultRun-Time UpdatedVolume SU with voice-20 to

Página 209

Appendix E E-17BreezeACCESS Version 4.5 System ManualProtocol ParametersParameter Unit Range DefaultRun-Time UpdatedGatekeeper OptionSU with voiceDis

Página 210

E-18BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Registration TTL SU with voice0 (not active), 1 – 65535 0 NoDTMF Relay SU with voiceDisa

Página 211

Appendix E E-19BreezeACCESS Version 4.5 System ManualNational Telephony ParametersParameter Unit Range DefaultRun-Time UpdatedTelephony Country Stand

Página 212

System Components 2-11BreezeACCESS Version 4.5 System ManualAU-I/I-D Miniature Indoor UnitsThe AU-I/I-D line includes miniature units that are designe

Página 213

E-20BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Cadence On in Call Progress Tones:Ring-Back, Busy, Congestion, Error, High Level ErrorSU

Página 214 - Other Bridging Parameters

Appendix E E-21BreezeACCESS Version 4.5 System ManualMax Make/Break RatioSU with voice30-330 (%) Country dependentNoMin Inter Digit TimeSU with voice2

Página 215

E-22BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Line Impedance SU with voice(Voice card rev. D and higher)0 – 600 Ohm1 – 900 Ohm2 – 6

Página 216

Appendix E E-23BreezeACCESS Version 4.5 System ManualRing Duration SU with voice(Voice card rev. D and higher)0-1000 seconds Country dependentNoParame

Página 217

E-24BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Special Features ParametersParameter Unit Range DefaultRun-Time UpdatedCaller ID SU wit

Página 218

Appendix E E-25BreezeACCESS Version 4.5 System ManualPulse Metering TimeoutSU with voice(Voice card rev. D and higher)0-100 seconds 3 seconds NoV5 Pul

Página 219

E-26BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Polarity During Outgoing Calls:Polarity in Ring Back StateSU with voice(Voice card rev.

Página 220

Appendix E E-27BreezeACCESS Version 4.5 System ManualPolarity During Incoming Calls:Polarity in Called Party Hangs-up First SU with voice(Voice card r

Página 221

E-28BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Hopping ParametersAlarm ParametersParameter Unit Range DefaultRun-Time UpdatedNumber of

Página 222

Appendix F:Hopping SequencesHopping Standard: AustraliaEach hopping sequence is comprised of 60 channels in the frequency band from 2402 MHz to 2461 M

Página 223

© 2003 by Alvarion Ltd. All rights reserved.No part of this publication may be reproduced in any material form without the written permission of the c

Página 224

2-12BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0Networking EquipmentThe base station equipment is connected to the backbone through

Página 225 - (Subscriber Units only)

F-2BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Actual Frequency: (2400+Channel) MHz Calculating the operational hopping sequence:IF [Pi(

Página 226

Appendix F F-3BreezeACCESS Version 4.5 System ManualHopping Standards: Canada, MexicoEach hopping sequence is comprised of 30 channels in the frequenc

Página 227 - Accounting Parameters Menu

F-4BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Hopping Standards: Europe ETSI, US FCC, InternationalEach hopping sequence is comprised o

Página 228 - RADIUS Record Structure

Appendix F F-5BreezeACCESS Version 4.5 System Manual Calculating the operational hopping sequence:IF [Pi(1, 1)+(S-1)x3+(H-1)]>80, than Pi(H, S) = P

Página 229

F-6BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Hopping Standards: FranceEach hopping sequence is comprised of 35 channels in the frequen

Página 230

Appendix F F-7BreezeACCESS Version 4.5 System ManualHopping Standards: IsraelEach hopping sequence is comprised of 35 channels in the frequency band f

Página 231 - Wireless Media Security

F-8BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Hopping Standards: JapanEach hopping sequence is comprised of 23 channels in the frequenc

Página 232 - Voice Parameters

Appendix F F-9BreezeACCESS Version 4.5 System ManualP17(1, 3) = [(17-1) x 12]mod23 + 73 = 192 mod23 + 73 = 8 + 73 = 81P18(1, 3) = [(18-1) x 12]mod23 +

Página 233

F-10BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Hopping Standards: KoreaEach hopping sequence is comprised of 23 channels in the frequen

Página 234 - Protocol Parameters

Appendix F F-11BreezeACCESS Version 4.5 System ManualP17(1, 3) = [(17-1) x 12]mod23 + 30 = 192 mod23 + 30 = 8 + 30 = 38P18(1, 3) = [(18-1) x 12]mod23

Página 235

System Components 2-13BreezeACCESS Version 4.5 System ManualBreezeCONFIGThe BreezeCONFIG ACCESS configuration utility can also be used to manage Breez

Página 236

F-12BreezeACCESS Version 4.5 System ManualManual Revision: 1.0Hopping Standards: SpainEach hopping sequence is comprised of 27 channels in the frequen

Página 237

Index 1-1BreezeACCESS Version 4.5 System ManualAAccess Link Parameter ..Book 4, 2-75Access to DHCP Parameter ..Book 4, 2-38Access to Network Managem

Página 238

1-2BreezeACCESS Version 4.5 IndexManual Revision:1.0AU-A/E-BSPacking List ..Book 2, 1-2AU-A/E-NI ...Book 1, 2-10Packing List ..Book 2, 1-3AU-I/I-DI

Página 239

Index 1-3BreezeACCESS Version 4.5 System ManualCCadence Off ..Book 4, 2-110Cadence Off Parameter ..Book 4, 2-110Cadence On ..Book 4, 2-110Cadence O

Página 240 - National Telephony Parameters

1-4BreezeACCESS Version 4.5 IndexManual Revision:1.0Delete All Network Management IP Addresses Parameter ...Book 4, 2-71Delete All User Filtering Ent

Página 241

Index 1-5BreezeACCESS Version 4.5 System ManualFrequency 2 Parameter ..Book 4, 2-110GG711A-law Frames Per Packet Parameter ..Book 4, 2-102G711u-law

Página 242

1-6BreezeACCESS Version 4.5 IndexManual Revision:1.0Indoor Units ..Book 2, 1-13Modular Base Station Equipment ..Book 2, 1-15Outdoor Units ..Book 2,

Página 243

Index 1-7BreezeACCESS Version 4.5 System ManualConfiguring . Book 3, 2-2Maximum Data Rate Parameter ..Book 4, 2-63Maximum Delay Parameter ..Book 4,

Página 244

1-8BreezeACCESS Version 4.5 IndexManual Revision:1.0Multi-Rate Decision Window Size Parameter ...Book 4, 2-87Multi-Rate Support Parameter ...Book 4,

Página 245 - Special Features

Index 1-9BreezeACCESS Version 4.5 System ManualPing Frame Timeout Parameter ..Book 4, 2-20Ping Test ..Book 4, 2-20Ports Control Parameter ..Book 4,

Página 246

2-14BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0

Página 247

1-10BreezeACCESS Version 4.5 IndexManual Revision:1.0Send Roaming SNAP ...Book 4, 2-68Send SNMP Traps Parameter ...Book 4, 2-71Send SU Associated AU

Página 248 - Line Testing

Index 1-11BreezeACCESS Version 4.5 System ManualTelephony . Book 1, 3-4Voice/Fax . Book 1, 3-4Start Sending Parameter ..Book 4, 2-21StatisticsPer H

Página 249

1-12BreezeACCESS Version 4.5 IndexManual Revision:1.0ToS Priority Parameters ...Book 4, 2-81Total received data frames Parameter ...Book 4, 2-18Tota

Página 250

Index 1-13BreezeACCESS Version 4.5 System ManualVLAN Forwarding Parameter ..Book 4, 2-77VLAN Forwarding Support Parameter ..Book 4, 2-78VLAN ID-Data

Página 251 - Hopping Parameters (GU)

1-14BreezeACCESS Version 4.5 IndexManual Revision:1.0

Página 252

Chapter 3SpecificationsThis chapter lists the technical specifications of BreezeACCESS and includes the following sections:! System Specifications‚ pa

Página 253 - Alarm Parameters (GU)

3-2BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0System Specifications Radio and Modem Parameter ValueFrequency 2.400-2.500 GHz (acc

Página 254 - Alarms Out Names

Specifications 3-3BreezeACCESS Version 4.5 System ManualBreezeACCESS II Radio Regulatory StandardsThe systems support different “country standards” f

Página 255 - Show Alarm Parameters

3-4BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0Voice/Fax (Subscriber Units with voice support)Telephony (Subscriber Units with voic

Página 256

Specifications 3-5BreezeACCESS Version 4.5 System ManualConfiguration and Management GU-RA GPS RadioGU-RA to BS-GU CommunicationMaximum IF Cable Atte

Página 257

3-6BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0EnvironmentalStandards Compliance, GeneralCable Impedance 100 +/- 15 ohm @ 1 MHz (RS

Página 258

Specifications 3-7BreezeACCESS Version 4.5 System ManualPhysical SpecificationsSU-A/E Subscriber Unit ConnectorsElectricalMechanicalUnit Connector De

Página 259 - Download/Upload

iiBreezeACCESS Version 4.5 System Manual(c) ALVARION SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEG

Página 260

3-8BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0AU-A/E-NI Stand-Alone Access UnitConnectorsElectricalMechanicalUnit Connector Descri

Página 261 - Loading Procedure

Specifications 3-9BreezeACCESS Version 4.5 System ManualModular Base Station EquipmentConnectorsUnit Connector DescriptionAU-A/E-BS AU-BS IF TNC jac

Página 262 - Loading an Upgrade to a Unit

3-10BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0Modular Base Station Equipment - ElectricalMechanicalUnit DetailsGeneral 200 W for

Página 263 - Appendix B

Specifications 3-11BreezeACCESS Version 4.5 System ManualSU-I/I-DConnectorsElectricalMechanicalConnector DescriptionAntenna (SU-I-D) 2 x SMA jacks, 5

Página 264

3-12BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0AU-I/I-DConnectorsElectricalMechanicalConnector DescriptionAntenna (AU-I-D) 2 x SMA

Página 265

Specifications 3-13BreezeACCESS Version 4.5 System ManualSU-R Subscriber UnitsConnectorsElectricalMechanicalConnector DescriptionAntenna 2 proprieta

Página 266

3-14BreezeACCESS Version 4.5 System DescriptionManual Revision: 1.0

Página 267 - SU-A/E, AU-A/E

BreezeACCESS II SW Version 4.5Revision 1.0System Manual Book 2:Installation

Página 269 - SU-R and SU-I

Chapter 1IF-BasedEquipmentThis chapter describes the basic installation of BreezeACCESS IF-based equipment, including SU-A/E subscriber units, modular

Página 270

Important NoticeiiiSU-I/I-D and AU-I/I-D 20 cm (8 inches)SU-R 20 cm (8 inches)R&TTE Compliance StatementThis equipment complies with the appropria

Página 271 - Unit Control Parameters

1-2BreezeACCESS Version 4.5 InstallationManual Revision: 1.0Packing ListsSU-A/E Subscriber Unit! SU-NI Indoor unit ! Outdoor unit:SU-RA with integral

Página 272 - Site Survey Parameters

IF Based Equipment 1-3BreezeACCESS Version 4.5 System ManualBS-PS DC Power Supply (one or two per chassis)! BS-PS power supply module! DC power cable

Página 273 - IP Parameters

1-4BreezeACCESS Version 4.5 InstallationManual Revision: 1.0! GPS cable (30, 60 or 120 meter – supplied separately according to order)*! SYNC cable* –

Página 274 - Air Interface Parameters

IF Based Equipment 1-5BreezeACCESS Version 4.5 System ManualGuidelines for Selection of Equipment LocationsSelect appropriate locations for the outdo

Página 275 - Run-Time

1-6BreezeACCESS Version 4.5 InstallationManual Revision: 1.0IF CableThe outdoor unit is connected to the indoor unit by means of an IF cable carrying

Página 276

IF Based Equipment 1-7BreezeACCESS Version 4.5 System ManualInstalling the Outdoor Unit The Outdoor Unit Bottom Panel The SU-RA and AU-RA outdoor uni

Página 277 - Parameters

1-8BreezeACCESS Version 4.5 InstallationManual Revision: 1.0Table 1-4: SU-RA/RE Bar Display DescriptionFigure 1-2: AU-RA/RE Bottom PanelTable 1-5: AU-

Página 278

IF Based Equipment 1-9BreezeACCESS Version 4.5 System ManualPole Mounting the Outdoor UnitThe outdoor unit can be secured to the pole using one of th

Página 279 - Bridge Parameters

1-10BreezeACCESS Version 4.5 InstallationManual Revision: 1.0Figure 1-3: Grooves/Threaded HolesFigure 1-4: 3" Pole Mounting Installation Using th

Página 280

IF Based Equipment 1-11BreezeACCESS Version 4.5 System ManualThe integral antenna of the AU-RA is relatively long. The top of the antenna should also

Página 281 - Performance Parameters

ivBreezeACCESS Version 4.5 System ManualImportant NoticeThis user manual is delivered subject to the following conditions and restrictions:! This ma

Página 282

1-12BreezeACCESS Version 4.5 InstallationManual Revision: 1.0Connecting the Antenna Cable (SU-RE and AU-RE)Connect an RF cable between the ANT connect

Página 283 - Service Parameters

IF Based Equipment 1-13BreezeACCESS Version 4.5 System ManualInstalling the SU-NI and AU-NI Indoor UnitFigure 1-7: SU-NI with Voice Support Rear Pane

Página 284 - RADIUS Parameters

1-14BreezeACCESS Version 4.5 InstallationManual Revision: 1.0The SU-NI/AU-NI provides the following interfaces:! An Ethernet connector (marked ETH) fo

Página 285

IF Based Equipment 1-15BreezeACCESS Version 4.5 System ManualInstalling Modular Base Station EquipmentBS-SH Slot AssignmentsThe base station chassis

Página 286

1-16BreezeACCESS Version 4.5 InstallationManual Revision: 1.0The BS-PSThe BS-PS provides power to all the modules installed in the BS-SH chassis. The

Página 287

IF Based Equipment 1-17BreezeACCESS Version 4.5 System ManualThe BS-PS-ACThe BS-PS-AC is an AC to DC converter that provides power to all the modules

Página 288

1-18BreezeACCESS Version 4.5 InstallationManual Revision: 1.0The BS-AUFigure 1-12: BS-AU Front PanelTable 1-9: BS-AU LEDsWARNING:If two power supply m

Página 289 - National Telephony

IF Based Equipment 1-19BreezeACCESS Version 4.5 System ManualThe BS-AU provides the following interfaces:! An Ethernet connector (marked ETH) for con

Página 290

1-20BreezeACCESS Version 4.5 InstallationManual Revision: 1.0power source and the black wire to the -48 VDC contact of the power source. Connect the r

Página 291

IF Based Equipment 1-21BreezeACCESS Version 4.5 System ManualInstalling the GU-A-BS GPS and Alarms SystemBS-GU Front PanelFigure 1-13: BS-GU Front Pa

Página 292

Table of Contents 1Manual Revision 1.0Table of ContentsSystem Manual Book 1:System DescriptionIntroduction ...

Página 293

1-22BreezeACCESS Version 4.5 InstallationManual Revision: 1.0Table 1-10: BS-GU ConnectorsTable 1-11: BS-GU LEDs and SwitchesConnector Name Functionali

Página 294 - Special Features Parameters

IF Based Equipment 1-23BreezeACCESS Version 4.5 System ManualInstalling the GU-RA GPS Antenna1. Screw the GPS antenna firmly to the special 1” thread

Página 295

1-24BreezeACCESS Version 4.5 InstallationManual Revision: 1.04. Connect the 12-pin round connector to the GPS antenna.5. Route the cable to the locati

Página 296

Chapter 2IndoorSU-R UnitsThis chapter explains how to install BreezeACCESS SU-R units and includes the following sections:! Packing Lists‚ page 2-2, l

Página 297

2-2BreezeACCESS Version 4.5 InstallationManual Revision: 1.0Packing ListsSU-R Subscriber UnitThe SU-R units are shipped with the following units and a

Página 298 - Alarm Parameters

Indoor SU-R Units 2-3BreezeACCESS Version 4.5 System ManualInstallation GuidelinesThis section describes the installation guidelines and the various

Página 299 - Hopping Sequences

2-4BreezeACCESS Version 4.5 InstallationManual Revision: 1.0! Position the antennas clear of metal furniture and away from moving metal objects such a

Página 300

Indoor SU-R Units 2-5BreezeACCESS Version 4.5 System ManualLightning protection entails connecting an antenna discharge unit (also called an arrestor

Página 301 - Hopping Standards: Canada

2-6BreezeACCESS Version 4.5 InstallationManual Revision: 1.0Connecting the Omni Antennas1. Connect the omni antennas to antenna ports 1 and/or 2 on th

Página 302 - US FCC, International

Indoor SU-R Units 2-7BreezeACCESS Version 4.5 System Manual1. Plug the output jack of the power transformer into the DC input jack (marked DC IN) loc

Página 303

2BreezeACCESS 4.5 System ManualAU-I/I-D ... 3-12SU-R Subscriber Units ...

Página 304 - Hopping Standards: France

2-8BreezeACCESS Version 4.5 InstallationManual Revision: 1.0

Página 305 - Hopping Standards: Israel

Chapter 3IndoorSU-I and AU-I UnitsThis chapter explains how to install BreezeACCESS SU-I and AU-I units and includes the following sections:! Packing

Página 306 - Hopping Standards: Japan

3-2BreezeACCESS Version 4.5 InstallationManual Revision 1.0Packing Lists SU-I/I-D Subscriber Unit! Subscriber Unit:SU-I with 2 integral omni antennas–

Página 307

Indoor SU-I and AU-I Units 3-3BreezeACCESS Version 4.5 System ManualFor local configuration of parameters:! A portable PC with Terminal Emulation sof

Página 308 - Hopping Standards: Korea

3-4BreezeACCESS Version 4.5 InstallationManual Revision 1.0Installation GuidelinesThis section describes the installation guidelines and the various c

Página 309

Indoor SU-I and AU-I Units 3-5BreezeACCESS Version 4.5 System Manualcapabilities. By using two antennas per unit, the system can select the best ante

Página 310 - Hopping Standards: Spain

3-6BreezeACCESS Version 4.5 InstallationManual Revision 1.0NOTE:Detached outdoors antennas should be installed ONLY by experienced antenna installatio

Página 311

Indoor SU-I and AU-I Units 3-7BreezeACCESS Version 4.5 System ManualInstalling SU-I/I-D and AU-I/I-D UnitsConnectors and LEDsThe unit provides the fo

Página 312 - Manual Revision:1.0

3-8BreezeACCESS Version 4.5 InstallationManual Revision 1.0Figure 3-3: SU-I Front PanelTable 3-2: SU-I LEDsName Description FunctionalityPOWER Power

Página 313

Indoor SU-I and AU-I Units 3-9BreezeACCESS Version 4.5 System ManualFigure 3-4:: AU-I Front PanelTable 3-3: AU-I LEDsName Description FunctionalityPO

Página 314

Table of Contents 3Manual Revision 1.0Antenna Diversity ...2-4Antenna Polarization ...

Página 315

3-10BreezeACCESS Version 4.5 InstallationManual Revision 1.0Wall Mounting the UnitUse the supplied brackets for wall mounting to install the unit on a

Página 316

Indoor SU-I and AU-I Units 3-11BreezeACCESS Version 4.5 System ManualConnecting Antenna(s) to the Units For installation convenience, a torque key is

Página 317

3-12BreezeACCESS Version 4.5 InstallationManual Revision 1.01. Plug the output jack of the power transformer into the DC input jack (marked DC IN 5V)

Página 318

BreezeACCESS II SW Version 4.5Revision 1.0System Manual Book 3:Commissioning

Página 320

Chapter 1SettingBasic ParametersThis chapter explains how to configure the basic parameters of the BreezeACCESS system and includes the following sect

Página 321

1-2BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0Accessing the Monitor ProgramAccessing the Monitor Program using the RS 232 MON Connector

Página 322

Setting Basic Parameters 1-3BreezeACCESS Version 4.5 System ManualFigure 1-1: Main Menu – Administrator Access Rights (SU and AU)The appearance of th

Página 323

1-4BreezeACCESS Version 4.5 CommissioningManual Revision: 1.0Table 1-2: Required Type of Ethernet Cable2. The Select Access Level menu appears. Select

Página 324

Setting Basic Parameters 1-5BreezeACCESS Version 4.5 System ManualConfiguring Basic Parameters in Access and Subscriber UnitsThe maximum output power

Comentários a estes Manuais