Alvarion BreezeACCESS 900 Manual de Instruções Página 272

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 324
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 271
E-2
BreezeACCESS Version 4.5 System Manual
Manual Revision: 1.0
Site Survey Parameters
Parameter Unit Range Default
Run-
Time
Updated
RSSI Display
Option
AU, SU RSSI, dBm RSSI Yes
AU Alarms
Option
IF-based AU Disable, Enable Disable Yes
Learning Period IF-based AU 1 – 1440 (minutes) 30 (minutes) Yes
Test Cycle IF-based AU 1 – 1440 (minutes) 10 (minutes) Yes
Retransmissions
Minor Alarm
Minimum Delta
IF-based AU 0 – 100 (%) 20 (%) Yes
Retransmissions
Minor Alarm
Threshold
IF-based AU 1 – 100 (%) 30 (%) Yes
Retransmissions
Major Alarm
Threshold
IF-based AU 1 – 100 (%) 60 (%) Yes
Dropped Frames
Minor Alarm
Minimum Delta
IF-based AU 0 – 100 (%) 10 (%) Yes
Dropped Frames
Minor Alarm
Threshold
IF-based AU 1 – 100 (%) 10 (%) Yes
Dropped Frames
Major alarm
Threshold
IF-based AU 1 – 100 (%) 20 (%) Yes
CRC Error
Minor Alarm
Minimum Delta
IF-based AU 0 – 100 (%) 20 (%) Yes
CRC Error
Minor Alarm
Threshold
IF-based AU 1 – 100 (%) 40 (%) Yes
CRC Error
Major Alarm
Threshold
IF-based AU 1 – 100 (%) 70 (%) Yes
Vista de página 271
1 2 ... 267 268 269 270 271 272 273 274 275 276 277 ... 323 324

Comentários a estes Manuais

Sem comentários